items. ▼ View Cart

New

Current

Showing posts with label - A -ConnectionTest cable 35-pin socket box. Show all posts
Showing posts with label - A -ConnectionTest cable 35-pin socket box. Show all posts

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 979

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 979

Move on to actuation with button F2

2.3. Check internal resistance of component M16/6m1 (Actuator motor).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test sequence

- Switch off ignition.

- Disconnect coupling M at component N3/10 (ME-SFI [ME] control unit).

- Measure resistance with multimeter between sockets (M.75) 75 and (M.74) 74 of the 126-pole socket box tester.

Specified value

- Resistor[1...10]ohms

Question

- Is the measurement value OK?

YES

The measurement value is OK.End of test

NO

The measurement value is not OK.Possible cause and remedy

- Lines between N3/10 (ME-SFI [ME] control unit) and M16/6m1 (Actuator motor)

- M16/6m1 (Actuator motor)

End of test

2.4. Check internal resistance of component M16/6 (Throttle valve actuator).

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 953

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 953

1.5. Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Test sequence

- Measure direct current with multimeter between sockets [F.4] 100 and [F.27] 123 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Amperage[0.1...0.3] A

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 924

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 924

Warning!Communication with ECU required.

4.2. Test current consumption of component Y22/9 (Intake manifold tumble flap switchover valve).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 919

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 919

1.3. Test voltage supply of circuit 87.

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test voltage supply of circuit 87.

Test sequence

- Measure direct voltage with multimeter between sockets [ F.2 ] 98 and [F.3] 99 of the 126-pole socket box tester.

- Measure direct voltage with multimeter between sockets [ F.4 ] 100 and [ F.5 ] 101 of the 126-pole socket box tester.

- Measure direct voltage with multimeter between sockets [ F.6 ] 102 and [ F.5 ] 101 of the 126-pole socket box tester.

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 880

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 880

1.4. Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Test sequence

- Measure direct current with multimeter between sockets [F.4] 100 and [F.27] 123 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Amperage[0.1...0.3] A

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 836

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 836

Warning!Communication with ECU required.

1.2. Test current consumption of component Y22/6 (variable intake manifold switchover valve).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 684

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 684

1.3. Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Test sequence

- Measure direct current with multimeter between sockets [F.4] 100 and [F.27] 123 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Amperage[0.1...0.3] A

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 652

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 652

Warning!Communication with ECU required.

2.3. Check component N10/1kR (Air pump or oil cooler fan relay).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 647

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 647

Warning!Communication with ECU required.

2.3. Check component N10/1kR (Air pump or oil cooler fan relay).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 543

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 543

1.3. Test voltage supply of circuit 87.

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test voltage supply of circuit 87.

Test sequence

- Measure direct voltage with multimeter between sockets [ F.2 ] 98 and [F.3] 99 of the 126-pole socket box tester.

- Measure direct voltage with multimeter between sockets [ F.4 ] 100 and [ F.5 ] 101 of the 126-pole socket box tester.

- Measure direct voltage with multimeter between sockets [ F.6 ] 102 and [ F.5 ] 101 of the 126-pole socket box tester.

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 542

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 542

1.2. Test voltage supply of circuit 30.

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test voltage supply of circuit 30.

Test sequence

- Measure direct voltage with multimeter between sockets [ F.2 ] 98 and [ F.16 ] 112 of the 35-pole socket box tester.

- Switch on ignition.

Specified value

- Voltage[11.0...15.0] V

Question

- Is the measurement value OK?

YES

The measurement value is OK.End of test

NO

The measurement value is not OK.Possible cause and remedy

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 521

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 521

Test 1: Check component Relay 'Fuel pump'.

1. Check component Relay 'Fuel pump'.

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test sequence

- Switch off ignition.

- Connect socket box (126-pin) to component N3/10 (ME-SFI [ME] control unit).

- Measure direct current with multimeter between sockets [F.4] 100 and [F.17] 113 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Amperage[0,1...0,3] A

- Component M3 (Fuel pump assembly) is switched on and is heard to run.

Question

- Is the measurement value OK?

YES

The test was okay.End of test

NO

The measurement value is not OK.Possible cause and remedy

- Lines to component N10/2kA (Fuel pump relay)

- N10/2kA (Fuel pump relay)

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 488

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 488

- Check voltage supply according to wiring diagram.

4. Check component Y16/2 (Heating system shutoff valve).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test current consumption of component Y16/2 (Heating system shutoff valve).

Test sequence

- Switch off ignition.

- Connect socket box (126-pin) to component N3/10 (ME-SFI [ME] control unit).

- Measure direct current with multimeter between sockets [F.4] 100 and [M.71] 71 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Amperage[0.7...1.2] A

Question

- Is the measurement value OK?

YES

The measurement value is OK.End of test

NO

The measurement value is not OK.Possible cause and remedy

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 476

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 476

1.3. Test voltage supply of circuit 87.

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test voltage supply of circuit 87.

Test sequence

- Measure direct voltage with multimeter between sockets [ F.2 ] 98 and [F.3] 99 of the 126-pole socket box tester.

- Measure direct voltage with multimeter between sockets [ F.4 ] 100 and [ F.5 ] 101 of the 126-pole socket box tester.

- Measure direct voltage with multimeter between sockets [ F.6 ] 102 and [ F.5 ] 101 of the 126-pole socket box tester.

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 463

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 463

- Y62y5 (Fuel injector cylinder 5)

4.1.4. Inspect component Y62y5 (Fuel injector cylinder 5) for leaks.

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Figure legend

- 055Measuring beakerY62 (Fuel injectors)

Test sequence

- Switch off ignition.

- Remove fuel rail together with component Y62y5 (Fuel injector cylinder 5).

- Bridge between sockets (F.4) 100 and (F.17) 113 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Component Y62y5 (Fuel injector cylinder 5) must not drip.

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 457

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 457

1.4. Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Test sequence

- Measure direct current with multimeter between sockets [F.4] 100 and [F.27] 123 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Amperage[0.1...0.3] A

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 450

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 450

- Y62y5 (Fuel injector cylinder 5)

1.1.4. Inspect component Y62y5 (Fuel injector cylinder 5) for leaks.

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Figure legend

- 055Measuring beakerY62 (Fuel injectors)

Test sequence

- Switch off ignition.

- Remove fuel rail together with component Y62y5 (Fuel injector cylinder 5).

- Bridge between sockets (F.4) 100 and (F.17) 113 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Component Y62y5 (Fuel injector cylinder 5) must not drip.

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 437

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 437

- Y62y2 (Fuel injector cylinder 2)

4.1.4. Inspect component Y62y2 (Fuel injector cylinder 2) for leaks.

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Figure legend

- 055Measuring beakerY62 (Fuel injectors)

Test sequence

- Switch off ignition.

- Remove fuel rail together with component Y62y2 (Fuel injector cylinder 2).

- Bridge between sockets (F.4) 100 and (F.17) 113 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Component Y62y2 (Fuel injector cylinder 2) must not drip.

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 431

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 431

1.4. Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Connect socket box to component N3/10 (ME-SFI [ME] control unit).

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

-

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Test current consumption of component N10/1kR (Circuit 87 relay, engine).

Test sequence

- Measure direct current with multimeter between sockets [F.4] 100 and [F.27] 123 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Amperage[0.1...0.3] A

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 424

Mercedes Benz Truck GLK 350 (204.956) V6-3.5L (272.991) Manufacturer Code Page 424

- Y62y2 (Fuel injector cylinder 2)

1.1.4. Inspect component Y62y2 (Fuel injector cylinder 2) for leaks.

Figure legend

- A -ConnectionTest cable 35-pin socket box

- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)

- 05 -35-pin socket box

- 050 -126-pin socket box

- 108 -Test cable 266 589 01 63 00

- N3/10 (ME-SFI [ME] control unit)

- II 1-63ConnectionTest cable

- III 64-126ConnectionTest cable

Warning!

- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).

Continue to test with button F2

Figure legend

- 055Measuring beakerY62 (Fuel injectors)

Test sequence

- Switch off ignition.

- Remove fuel rail together with component Y62y2 (Fuel injector cylinder 2).

- Bridge between sockets (F.4) 100 and (F.17) 113 of the 126-pole socket box tester.

- Switch on ignition.

Specified value

- Component Y62y2 (Fuel injector cylinder 2) must not drip.

© E-commerce Blogger powered by 168 MOTIVE Shopping Mall . | Back To Top